Belt scale controller UNI900B
Belt scale controller UNI900B
Product Details

Selection Table

Belt scale controller UNI900B

Application diagram



Belt scale controller UNI900B


Application field

Belt (spiral) measuring scale, belt (spiral) batching scale.


Feature

  • The instrument has passed strict space radiation, high-voltage electrostatic discharge, and high and low temperature environmental testing, and has high reliability
  • All metal casing, physically isolated switch input/output and analog input/output, with customizable functions, flexible use, and reliable operation
  • Two AO outputs, a single instrument can control two belt feeders to achieve the batching function of the belt scale
  • Support physical calibration, hanging code calibration, and feeder linear calibration
  • Fast convergence filtering algorithm, fast data tracking speed, stable display
  • Advanced model control algorithm can accurately predict the effect of each control value, adjust the control quantity in advance, respond quickly, and overshoot is small
  • Second level PID algorithm, with faster control speed and higher accuracy
  • Equipped with accumulation control and moisture compensation functions
  • Has volume measurement mode function
  • Equipped with parameter backup and recovery functions to prevent accidental modification of instrument parameters
  • Multiple instruments can form a master-slave batching system through CAN interface
  • Supports RS232/RS485 communication interface (Modbus RTU protocol) and fieldbus interfaces such as CAN, Modbus TCP, Profibus DP, etc
  • Chinese menu, user-friendly human-computer interaction


Technical Specifications

projectTechnical Specifications
power supply180VAC~265VAC,50/60HZ
power consumption≈ 18 watts (including 8 standard sensor loads)
Operating Temperature-5 ℃~65 ℃ (23 ° F to 137 ° F)
weight≈2.7kg
Analog output path1 route/2 routes/3 routes (*)
Switching input path4/8 isolated inputs (*)
Switching outputThe maximum driving capacity of resistive load is 0.5A per circuit, with a total of 3A (A) points
Numerical displayHigh brightness fluorescent display tube (VFD display)
display range100-500,000
Applicable sensor typesAll resistance strain type weighing sensors
Sensor input voltageDC voltage of 10V ± 5%, capable of providing a maximum current of 250mA
Output sensitivity0.3 μ V/grid~0.30mV/grid
input impedanceAt DC500V, the impedance between each terminal shall not be less than 100MQ
Effective input voltage range0.03mV~30.0mV
nonlinear error≤ 0.005% of full scale
sampling rateUp to 200 times per second
Internal resolution1/16,000,000