| performance | CD200 instrument | Traditional parallel scale instruments |
| calibration | Exemption from weight calibration | Need to calibrate weights |
| Sensor signal access | The sensor is directly connected to the CD200 instrument | Parallel connection of sensors to weighing instruments |
| fault detection | Real time detection of sensors, displaying the fault information of which sensor directly when there is a fault; Faults such as disconnection of the excitation line or short circuit of the signal line, disconnection of the signal line, short circuit of the excitation line, and reverse connection of the signal line can be detected for easy maintenance and use | Unable to detect fault information in a timely manner or display fault information as a whole, further troubleshooting is required |
| display | OLED display screen, Chinese interface, user-friendly human-computer interaction | Generally displayed on digital tubes, with poor human-computer interaction |
| Angle difference adjustment | The angle difference can be adjusted directly on the instrument, which is convenient and fast | There is no angle difference adjustment function on the instrument, it needs to be adjusted on the junction box, and the adjustment range is relatively small |
| troubleshooting | The sensor has a fault, and the fault-tolerant algorithm of the instrument ensures the uninterrupted operation of the system. After shutdown, the fault can be checked based on the alarm information to reduce losses | The sensor is malfunctioning and cannot continue production |
| communication | Two independent communication channels, RS-485 and CAN interface | Generally, there is only one communication interface available |
| expand | Can be integrated into PWC systems, can communicate via CAN bus, distributed installation, no need to write communication programs, data can be directly uploaded and transparently mapped | Need to write a specialized PLC communication program |
| project | Technical Specifications |
| power supply | DC 24V (18-36V) |
| power consumption | Maximum power 7W |
| Operating Temperature | From -5 ℃ to 45 ℃ |
| humidity | ≤ 90% relative humidity |
| sampling method | Delta sigma method |
| sampling rate | Up to 200 times per second |
| Supply bridge voltage | 5VDC |
| Instrument sensitivity | 0.5 μ V/grid~200 μ V/grid |
| Internal resolution | 1/1600 ,0000 |
| Display division spacing | 1. 2, 5, 10, 20, 50 |