The IM2000 online infrared moisture measuring instrument is used for continuous and non-contact measurement of moisture in various materials. It can quickly and continuously measure on a conveyor belt, and non-contact measurement of the measured material can achieve online dynamic real-time detection with fast reaction time, and can achieve real-time control of product moisture content.
Feature
Continuous measurement, online dynamic real-time detection
Advantage
- Continuous and online measurement, directly involved in automatic control
- Unrelated to the flow rate of materials, fast response speed
- Non contact measurement, not affected by material wear and tear
- Easy calibration and maintenance
- Adopting a large lens (4 inches) to reduce the impact of dust
- Adopting tri frequency measurement for higher accuracy
Structure and Performance
- Design optical path compensation, automatically correct the impact of optical path drift, and ensure stable performance
- Integrated opto mechatronics system with built-in microcontroller
- Can eliminate the influence of steam and dust on the lens
- Using compressed air for cooling
- The secondary instrument can be calibrated, calibrated, set, diagnosed and other operations at any time
- The current output is 4-20mA, and serial port RS485 output can also be optionally selected
Application field
Suitable for online measurement of moisture content of granular, fibrous, powdery, flaky and other materials in various industries such as artificial board, particleboard, glass, food, papermaking, fiberglass, ceramic granules, mineral products, etc.
Installation dimension drawing

Main technical parameters
| project | parameter |
| measurement range | 0-50% |
| accuracy | Depending on the application, it can generally reach 0.2~0.3%; Or 5% of the measuring range |
| repetitiveness | ±0.2% |
| measure area | 120mm (standard measurement distance) |
| measure distance | 275mm±50mm |
| ambient temperature | 0-50℃ |
| ambient humidity | ≤90% |
| response time | 1s |
| power supply | AC100~240V,40~60Hz |
| power | MAX 55W |
| Light interference | The measuring location should avoid direct sunlight (the ambient light intensity does not affect it) |
| temperature effect | Equipped with temperature compensation |